Argus · Edge computer

Failsafe to PID < 100 ms

Argus

The edge computer that runs Acaysia.

CPU, GPU and FPGA in one enclosure, installed beside your PLC.

Argus exploded: the finned lid lifted above the open enclosure, the four walls pulled away, and the CPU module, the GPU card and the FPGA module raised above the carrier board.
  • Central processing unit

    CPU

    The plant side

    Talks to the PLCs you already run, keeps the historian and retrains the models on-premises.

  • Graphics processing unit

    GPU

    The optimizer

    Every control cycle, it simulates thousands of candidate trajectories and picks the best.

  • Field-programmable gate array

    FPGA

    The timekeeper

    Deterministic timing for the watchdogs and the hand-back to your PID in under 100 ms.

Argus, assembled and then exploded: the lid lifts, the walls slide away, and the CPU module, the GPU card and the FPGA module rise off the carrier board, each shown in turn.

Hardware

Built for any process, in any plant

The Acaysia Control System

Argus, our edge compute appliance, in development. MPPI optimization for physical processes, drop-in deployment, millisecond failsafe, continuous learning.

Argus, assembled, seen from the back: a finned enclosure with the connector openings in its rear wall.
Argus CPU · GPU · FPGA
  • CPUCentral processing unit The plant side

    Speaks OPC UA and EtherNet/IP to the PLCs you already run, keeps the historian, serves the operator dashboard, and retrains models on-premises with versioned rollback.

  • GPUGraphics processing unit The optimizer

    Every control cycle, it simulates thousands of candidate control trajectories on the process model and picks the best: MPPI on the AcaysiaRT GPU runtime.

  • FPGAField-programmable gate array The timekeeper

    Deterministic timing, independent of the software above it: the watchdogs, the health monitors and the hand-back to your PID in under 100 milliseconds.

Deployment journey

Shadow · Advisory · Closed loop

From observation to optimization, in controlled stages.

Control is handed over in stages. The system runs in shadow and advisory first, so it never gets more autonomy than it has earned.

  1. 01Observes

    Shadow mode

    30 days

    Install the edge unit near the PLC and connect over standard protocols. The system observes reactor dynamics for 30 days, learning behavior without touching control, and compares its predictions against actual PID performance.

  2. 02Recommends

    Advisory mode

    Operators keep full control

    The system provides optimization recommendations while operators maintain full control. Review predictions, build confidence in the model and refine safety constraints to plant-specific requirements.

  3. 03Controls

    Closed-loop control

    Inside your safety envelope

    Autonomous operation within your defined safety envelope. The system co-manages control with PID and reverts automatically on any fault or operator request. Full audit trail and event logging maintained.

  4. OngoingImproves

    Continuous optimization

    Every batch cycle

    Models improve with every batch cycle. On-premises retraining with versioned rollback improves performance continuously while maintaining safety guarantees.

Integration

Detailed specifications under NDA

Works with the infrastructure you already have.

Argus sits next to your PLC and respects every interlock it already has. OPC UA and EtherNet/IP connect to the PLCs you already run, with IEC 62443 cybersecurity considerations throughout. No rip and replace.

Works with

  • Siemens
  • Rockwell Automation
  • Beckhoff
  • Schneider Electric
  • ABB
  • OPC UA

Specifications

Compute
CPU + GPU + FPGA
Placement
Beside the PLC. Brownfield drop-in.
Protocols
OPC UA, EtherNet/IP
Supervision
Trust Arbiter. Every control move is checked against your limits before it reaches the plant.
Failsafe
Reverts to plant PID in < 100 ms
Safety
ASIL-D inspired, SIL compatible. Never interferes with your safety instrumented system. Shadow Mode is read-only.
Monitoring
Multi-layer watchdogs and health monitors
Operator dashboard
Setpoints, constraints and confidence. Historian replay and one-click rollback.
Data
On-premises time-series storage, secure export for retraining
Models
Retrained on-premises, with versioned rollback
Isolation
Complete air-gapping available
Detailed specifications
Under NDA Request access

Discovery call

Chemicals · pharmaceuticals · process industries

See Argus on your process.

Argus is in prototyping now. It installs beside your PLC and runs in shadow mode for 30 days before it touches control.